A turned journal is on hold. The inspection sheet gives a total indicator reading (TIR) of 0.024 mm. The drawing allows 0.010 mm circularity. Subtract the two numbers and the apparent excess is 0.014 mm. That is a poor basis for a regrind. The journal rotates about the spindle axis while a fixed radial indicator records changes in surface position. A circularity evaluation fits each cross section about its own center. Changing the reference center can change the reported value even when every measured point stays in place.
What made the indicator move?
Picture a perfectly round journal mounted slightly off center, with its axis parallel to an ideal inspection spindle. Keep a radial indicator at one axial station and turn the part once. The high reading comes as the journal center swings toward the probe. Half a turn later the center is farthest away. The dial moves even though the section would fit exactly on a single circle drawn about its own center.

An actual turned surface can have an uneven profile as well as an offset. The dial records their combined effect. A worksheet that saves only the high and low readings loses where the peaks occurred and how the rest of the surface ran between them. Subtracting an estimated setup offset from that swing cannot reconstruct the profile.
The example uses an ASME Y14.5-2018 circularity callout on an outside journal. Circularity is also called roundness. For this straight journal, take the sections perpendicular to the axis of the smallest perfect cylinder enclosing the journal. Within each section, the entire outline must fit between two concentric circles. The allowed radial gap is 0.010 mm. The two circles share a center within that section, and the callout has no datum reference. If the drawing also calls for circular runout relative to a bearing datum, preserve that relationship during the runout check. A chuck represents the specified datum axis only if the setup actually establishes it. The guide to concentricity and runout explains that separate drawing requirement.
One journal trace, three reference centers
Take 720 illustrative points around one full turn of a nominal 20 mm journal. Keep the section, points and filtering identical for all three rows. The radii below come from point coordinates. A shop dial by itself shows only changes in probe position. For each center, calculate the distance to every point. The shortest and longest distances are the radii of two concentric circles that enclose those points.
| Center used on the same trace | Smallest radius (mm) | Largest radius (mm) | Radial gap (mm) |
|---|---|---|---|
| Inspection spindle center | 9.9910 | 10.0150 | 0.0240 |
| Least-squares circle center | 9.9951 | 10.0060 | 0.0109 |
| Trial center shifted 0.0022 mm from the least-squares center | 9.9942 | 10.0038 | 0.0096 |

The second row could still put the part on hold. A least-squares fit chooses the circle that minimizes the sum of squared radial departures. The minimum-zone method looks for the center that gives the smallest gap between the enclosing circles. Those goals can put the center in different places. Mitutoyo illustrates both constructions in the Roundtest section of its guide to roundness measurement.
At the trial center used in the third row, all 720 points lie between two concentric circles about 0.0096 mm apart radially. This gives an upper bound on the minimum-zone width for those points. The measured points therefore fit inside the 0.010 mm zone. A gap above the limit at one trial center leaves open the possibility of a narrower gap at another center. If the purchase specification requires a particular evaluation method, use that method for the reported result.
What belongs on the journal’s inspection record?
For this journal, the useful record pairs each axial station with its full-turn trace, the circle-fitting method and the radial result. On a rotary roundness tester, center and level the part before taking the trace. A tilted setup can send the probe through an oblique section of a round cylinder. Moving the circle center afterward cannot change which section the probe touched.
The example uses 720 readings at one station. For the actual journal, specify where to take each trace and how closely to space the readings around each turn. Identify each station by its distance from the shoulder and keep the probe clear of the fillet. Save the filter setting with the trace so a second evaluation retains the same surface detail. Report the largest circularity result across the measured stations. A single measured ring leaves the rest of the journal unexamined. Hexagon’s circularity evaluation notes explain how section locations and point coverage affect the result. If the drawing controls the form of the whole surface between two coaxial cylinders, the cylindricity guide covers that evaluation.
On this inspection sheet, keep 0.024 mm in the spindle-sweep field. At the illustrated station, the trial enclosure leaves about 0.0004 mm (0.4 µm) to the limit. Apply the agreed decision rule with the measurement uncertainty before releasing the journal. A supplier quoting a corrective grind would need a confirmed form error and enough stock to keep the finished diameter within size limits. The 0.014 mm difference that first put this part on hold gives the grinder neither the depth nor the location of a cut.





