Profile Tolerance Across the Width of a CNC Cam Track

The inspection sketch for a milled cam block shows one scan running up the middle of the track. It follows the roller’s path from the low flat, up the ramp and onto the high flat. The drawing calls for a surface profile tolerance across the full 24 mm width. The proposed scan could follow the correct shape from end to end and still miss a high spot beside its path.

Before accepting that inspection scope, ask the supplier to draw the proposed scan paths on a top view of the track. Where those paths run matters as much as how many points the machine collects.

Which part of the track does the callout cover?

On this example drawing, a leader identifies the working face from the low flat to the high flat, including the blends into the ramp. The side faces and edge breaks are outside the indicated area. The basic dimensions and the referenced CAD model define the nominal shape. A section view makes the rise easy to see, even though the requirement extends across the width of the track.

A profile of a line callout controls the line element in each cross section to which the callout applies. Use the drawing to identify the section planes and the extent of the control. A profile of a surface callout establishes a three-dimensional zone over the indicated face. A row of points down the middle supplies one section of evidence for that face. Adding points along the centerline gives a more detailed trace. The strips on either side remain unmeasured. KEYENCE illustrates the difference between line and surface profile zones.

Top view of a cam track showing one centerline scan and the unmeasured working surface on either side.

The example uses an ASME Y14.5 drawing. It references the mounting base A first, the long locating side B second and the end stop face C third. These three nominally perpendicular faces establish the frame in which the track is located in the assembly. The supplier can use different fixtures for milling and inspection. The inspection still has to establish the datum reference frame specified on the drawing.


Three heights across one section of the low flat

Take one station halfway along the low flat, where the roller dwells at a constant height. The nominal face here is parallel to datum plane A at a basic height of 18.000 mm. Assume the drawing specifies a total surface profile tolerance of 0.20 mm, equally disposed about the nominal surface. At this flat station the boundaries are 17.900 mm and 18.100 mm. A drawing that places the zone to one side needs a different reading, as the unilateral profile tolerance guide explains.

The following example readings all come from the same lengthwise station and use the same datum alignment. Positive deviation points out of the material. The two outer readings are on the working face, clear of the edge breaks.

Position across the low flatMeasured height from ADeviation from nominal
Near the left side18.040 mm+0.040 mm
Centerline18.020 mm+0.020 mm
Near the right side18.140 mm+0.140 mm

The center reading is inside the zone. The right-hand reading is 0.040 mm above its upper boundary. Only 0.10 mm of the total 0.20 mm tolerance is available on the high side. These figures describe the geometry of the example. For an actual acceptance decision, apply the agreed measurement decision rule.

Plot of three heights on a cam dwell with the right-hand reading above the 18.100 mm upper boundary.

Height above A works for this calculation because the flat is parallel to A and the readings are well away from a blend. On the ramp and through the blends, evaluate each measured point’s deviation along the local normal to the nominal surface in the A–B–C datum frame. That normal is tilted on the straight ramp and changes direction through each blend. Carrying the flat’s height limits up the incline would flag even a correctly machined rise.


Can the supplier recover the missing evidence?

Suppose the first-article report shows only the center trace. Ask for the path plot and the underlying measurement record. The supplier may already have scanned across the width but exported only a section for the report. If the stored data include the measured datum features and adequate coverage of the track, the supplier can evaluate the points together in the drawing’s frame and identify the sampled point farthest from nominal. Fitting each strip independently could shift a high strip toward nominal and hide its height relative to the mounting base.

If the probe visited only the centerline, the record contains no measurements from either side of the dwell. A transverse pass at the station in the example would show how height changes across that flat. For first-article coverage, also agree where the probe will follow the rise and cross the blends, and how close it can get to the working edges. The three example readings demonstrate one missed high spot. They do not set a sampling plan for the rest of the face. Hexagon’s surface profile documentation shows how sparse measurements can understate the zone needed to contain the actual surface.

Ask the supplier to price a datum-aligned surface profile result for the indicated track and to include the scan paths and the location of the largest reported departure. The CMM inspection guide covers the rest of the report. If the supplier already holds suitable data, a revised report may be enough. If the only scan runs down the center and its readings are within limits, the supplier needs measurements across the width before accepting the track. If a measured point already establishes nonconformance under the agreed decision rule, the supplier can hold the part and use further measurements to determine how much of the track is affected.